Code: C2558
Description: Abnormally high toner density detected TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Remedy: 1 Make sure that the following counter is cleared at the developer replacing. [Service Mode] - [Counter] - [Life] - [Developer Use Time] 2 Perform image troubleshooting procedure if image density is low. 3 Reinstall developing unit. 4 Reinstall toner bottle. 5 Check the contact of developing unit for proper connection and correct as necessary. 6 Check the connector between TCRSB CN29-relay CN28-PRCB CN24 for proper connection and correct as necessary. 7 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 8 Check the connector between M4-relay CN13-PRCB CN8 for proper connection and correct as necessary. 9 M3 operation check. 10 M4 operation check. 11 Change developing unit. 12 Change TCRSB. 13 Change PRCB.