Description: Tray 1 feeder up/down abnormality. The tray 1 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Remedy: 1. Check the connector between M12-MFPB CN7E for proper connection and correct as necessary. 2. Check the connector of M12 for proper drive coupling and correct as necessary. 3. Check the connector between PS22-relay CN48-MFPB CN10E for proper connection and correct as necessary. 4. PS22 I/O check, sensor check • Control signal: MFPB CN10E-8 (ON) • Location of electrical component: 4-C 5. M12 operation check • Control signal:MFPB CN7E-1 to 2 • Location of electrical component: 7-C 6. Replace M12. 7. MFPB F5E conduction check 8. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub 367/287/227)