Description: Abnormally low toner density detected black TCR sensor. When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the toner hopper.
Remedy: 1. Perform image troubleshooting procedure if image density is low. 2. Reinstall developing unit/K. 3. Reinstall toner cartridge/K. 4. Check the connector between the developing unit-relay CN15-MFPB CN17E for proper connection and correct as necessary. 5. M10 operation check • Control signal: MFPB CN22E-5 to 8 • Location of electrical component: 20-J 6. M6 operation check • Control signal: MFPB CN22E-1 to 4 • Location of electrical component: 20-J 7. If the toner empty sensor and its surroundings inside the toner hopper are dirtied with toner, clean them. 8. Replace the developing unit/K. 9. MFPB F13E, F14E conduction check 10. Replace MFPB.