Mã lỗi C8101 — Konica-Minolta bizhub 367

Code: C8101

Description: Before reading pressure welding alienation . mechanism (When DF-628 is installed). • During a pressure motion being performed, the original reading sensor (PS4) output does not change from H to L. • During a retraction motion being performed, the original reading sensor (PS4) output does not change from L to H.
Causes: • Reading roll release motor (M5) • Original reading sensor (PS4) • DF control board (DFCB)
Remedy: 1. Check the connector between M5-DFCB J18 for proper connection and correct as necessary. 2. Check the connector of M5 for proper drive coupling and correct as necessary. 3. Check the connector between PS4-DFCB J10 for proper connection and correct as necessary. 4. PS4 I/O check, sensor check • Control signal: DFCB J10-3 (ON) • Location of electrical component: DF-628 2-G 5. M5 operation check • Control signal: DFCB J18-4 to 5 • Location of electrical component: DF-628 2-G 6. Replace M5. 7. DFCB F9 conduction check. 8. Replace DFCB.