Code: 843.02
Description: Generic Mechanical failure detected
Remedy: Step 1: Check all cables connecting the ADF and flatbed to the controller board. Are they properly connected? Yes: Go to step 3. No: Go to step 2.
Step 2: Re-connect the cables to the controller board. Did this fix the problem? Yes: The problem is solved. No: Go to step 3.
Step 3: 1. Enter diagnostics mode and navigate to: SCANNER TESTS >Sensor Test Perform the scanner sensor tests. 2. Navigate to: SCANNER TESTS >Motor Tests Perform the scanner sensor and motor tests. Did any test fail? Yes: Go to step 4. No: Go to step 8.
Step 4: Did the Flatbed Home Sensor test or Flatbed motor test fail? Yes: Go step 5. No: Go to step 6.
Step 5: Replace the flatbed. Did this solve the problem? Yes: The problem is solved. No: Go to step 6.
Step 6: Did the ADF pick motor or feed motor tests fail? Yes: Go to step 7. No: Go to step 8.
Step 7: Replace the ADF. Did this fix the problem? Yes: The problem is solved. No: Go to step 8.
Step 8: Replace the controller board. Did this fix the problem? Yes: The problem is solved. No: Contact the next level of support.
Step 2: Re-connect the cables to the controller board. Did this fix the problem? Yes: The problem is solved. No: Go to step 3.
Step 3: 1. Enter diagnostics mode and navigate to: SCANNER TESTS >Sensor Test Perform the scanner sensor tests. 2. Navigate to: SCANNER TESTS >Motor Tests Perform the scanner sensor and motor tests. Did any test fail? Yes: Go to step 4. No: Go to step 8.
Step 4: Did the Flatbed Home Sensor test or Flatbed motor test fail? Yes: Go step 5. No: Go to step 6.
Step 5: Replace the flatbed. Did this solve the problem? Yes: The problem is solved. No: Go to step 6.
Step 6: Did the ADF pick motor or feed motor tests fail? Yes: Go to step 7. No: Go to step 8.
Step 7: Replace the ADF. Did this fix the problem? Yes: The problem is solved. No: Go to step 8.
Step 8: Replace the controller board. Did this fix the problem? Yes: The problem is solved. No: Contact the next level of support.