Code: 940.xx
Description: Controller to engine communication failure - the zero crossing signal used for fuser control in the low voltage (LV) power supply has failed, or the wrong low voltage power supply has been installed.
Remedy: Step 1: 1. Check the power cord for continuity. If necessary, replace. 2. Make sure the nominal voltage source is within specification. Does the problem remain? Yes: Go to step 2. No: The problem is solved.
Step 2: Check if the power supply cable is properly connected to the controller board. Is it properly connected? Yes: Go to step 3. No: Reseat the cables.
Step 3: 1. Turn off the printer. 2. Remove the power cord. 3. Measure the resistance between terminals A and D of the power supply socket. Is the resistance approximately 30 ohms? Yes: Contact your next level of support. No: Replace the power supply.
Step 2: Check if the power supply cable is properly connected to the controller board. Is it properly connected? Yes: Go to step 3. No: Reseat the cables.
Step 3: 1. Turn off the printer. 2. Remove the power cord. 3. Measure the resistance between terminals A and D of the power supply socket. Is the resistance approximately 30 ohms? Yes: Contact your next level of support. No: Replace the power supply.