Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 0F36 — Konica-Minolta bizhub 42

Code: 0F36

Description: Abnormally low toner density detected TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Make sure that the following counter is cleared at the developer replacing. [Service Mode] -> [Supplies] -> [Life Counter Clear] -> [Developer (K)] 2 Perform image troubleshooting procedure if image density is low. 3 Reinstall developing unit 4 Reinstall toner bottle 5 Check the contact of developing unit for proper connection and correct as necessary. 6 Check the connector between TCRSB CN29-relay CN28- PRCB CN24 for proper connection and correct as necessary. 7 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 8 Check the connector between M8-relay CN13-PRCB CN8 for proper connection and correct as necessary. 9 M3 operation check 10 M8 operation check 11 Change developing unit 12 Change TCRSB 13 Change PRCB

← Xem tất cả mã lỗi Konica-Minolta bizhub 42

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie