Code: C-1117
Description: FS-522: Alignment motor /Fr (M5) drive abnormality.
- While in the home position search, the alignment home sensor /Fr (PS7) does not turn ON within a specified period of time after M5 turns ON.
- While in the home position search, PS7 does not turn OFF within a specified period of time after M5 turns ON.
- While in the home position search, the alignment home sensor /Fr (PS7) does not turn ON within a specified period of time after M5 turns ON.
- While in the home position search, PS7 does not turn OFF within a specified period of time after M5 turns ON.
Causes: Alignment motor /Fr (M5) Alignment home sensor /Fr (PS7) FS control board (FSCB)