Description: Tray 2 feeder up/down abnormality. The tray 2 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Causes: • Tray 2 lift-up motor (M13) • Tray 2 upper limit sensor (PS22) • Printer control board (PRCB)
Remedy: 1 Check the connector between M13-PRCB CN20 for proper connection and correct as necessary. 2 Check the connector of M13 for proper drive coupling and correct as necessary. 3 Check the connector between PS22-relay CN40- PRCB CN19 for proper connection and correct as necessary. 4 PS22 I/O check, sensor check PRCB CN19-9 (ON) 9-C 5 M13 operation check PRCB CN20-5 (REM) 2-C 6 Replace M13 7 PRCB ICP4 conduction check 8 Replace PRCB