Code: C1140
Description: Alignment plate motor/Rr’s malfunction. <When FS-533 is installed> • The alignment plate home sensor/R (PS109) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate home sensor/R (PS109) is not blocked after the set period of time has elapsed when the plate returns to the home position. <When FS-534 is installed> The alignment plate/R home sensor (PS13) is not blocked or unblocked even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized. <When FS-535 is installed> The alignment plate motor home sensor/Rr (PS18) is not blocked even after the set period of time has elapsed while the alignment plate motor/Rr (M12) is energized.
Causes: <When FS-533 is installed> • Alignment motor/R (M106) • Alignment plate home sensor/R (PS109) • FS control board (FSCB) <When FS-534 is installed> • Alignment motor/Rear (M8) • Alignment plate/R home sensor (PS13) • FS control board (FSCB) <When FS-535 is installed> • Alignment plate motor/Rr (M12) • Alignment plate motor home sensor/Rr (PS18) • FS control board (FSCB)
Remedy: When FS-533 is installed: 1 Check the connector between M106-FSCB CN102 for proper connection and correct as necessary. 2 Check the connector of M106 for proper drive coupling and correct as necessary. 3 Check the connector between PS109-relay CN106- FSCB CN102 for proper connection and correct as necessary. 4 PS109 I/O check, sensor check FSCB CN102 FS-533 7-J 5 M106 operation check FSCB CN102 FS-533 8-J 6 Replace M106 7 FSCB CP105 conduction check 8 Replace FSCB. When FS-534 is installed: 1 Check the connector between M8-FSCB J12 for proper connection, and correct as necessary. 2 Check the connector of M8 for proper drive coupling, and correct as necessary. 3 Check the connector between PS13-FSCB J9 for proper connection, and correct as necessary. 4 PS13 I/O check, sensor check FSCB J9<B>-9 (ON) FS-534 9-C 5 M8 operation check FSCB J12-13 to 16 FS-534 5 to 6-C to D 6 Replace M8 7 Replace FSCB. When FS-535 is installed: 1 Check the connector between M12-FSCB CN19 for proper connection, and correct as necessary. 2 Check the connector of M12 for proper drive coupling, and correct as necessary. 3 Check the connector between PS18-FSCB CN20 for proper connection, and correct as necessary. 4 PS18 I/O check, sensor check FSCB CN20-3 (ON) FS-535 11-D 5 M12 operation check FSCB CN19-5 to 8 FS-535 10-D 6 Replace M12 7 Replace FSCB