Description: Toner bottle cooling fan’s failure to turn. <bizhub 454e> The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Toner bottle cooling fan (FM4) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM4-relay CN111- PRCB CN36 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check PRCB CN36-2 (REM) PRCB CN36-3 (LOCK) 26-C 4 Replace FM4 5 PRCB ICP18 conduction check 6 Replace PRCB