Description: Fusing power supply cooling fan’s failure to turn. <bizhub 454e> The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Fusing power supply cooling fan (FM12) • Expansion control board (EXCB) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM12-EXCB CN6 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM12 operation check EXCB CN6-1 (REM) EXCB CN6-3 (LOCK) 23-T 4 Replace FM12 5 EXCB ICP1 conduction check 6 Replace EXCB 7 Replace PRCB