Description: Slider over running. The scanner home sensor (PS201) detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed.
Causes: • Scanner home sensor (PS201) • Scanner motor (M201) • Scanner drive board (SCDB) • Printer control board (PRCB)
Remedy: 1 Correct or change the scanner drive (pulley, gear, belt) if it is faulty. 2 Correct the scanner motor set screw if loose. 3 Adjust [Image Position: Leading Edge] and [Sub Scan Zoom Adj.]. 4 Check the connector between M201-SCDB PJ4 for proper connection and correct as necessary. 5 Check the connector between PS201-SCDB PJ6 for proper connection and correct as necessary. 6 Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary. 7 PS201 I/O check, sensor check SCDB PJ6-3 (ON) 27-P 8 M201 operation check SCDB PJ4-1 to 4 27-P 9 Replace SCDB 10 Replace PRCB