Description: Before reading pressure welding alienation mechanism trouble. • During a pressure motion being performed, the document reading sensor (PS6) output does not change from H to L. • During a retraction motion being performed, the document reading sensor (PS6) output does not change from L to H.
Causes: • Reading roller release motor (M4) • Document reading sensor (PS6) • DF control board (DFCB)
Remedy: 1 Check the connector between M4-DFCB J18 for proper connection and correct as necessary. 2 Check the connector of M4 for proper drive coupling, and correct as necessary. 3 Check the connector between PS6-DFCB J10 for proper connection and correct as necessary. 4 PS6 I/O check, sensor check DFCB J10-3 (ON) DF-701 2-G 5 M4 operation check DFCB J18-4 to 5 DF-701 1-G 6 Replace M4 7 FSCB F8 conduction check 8 Replace DFCB