Description: Exposure LED lighting failure. The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.
Causes: • LED exposure unit (LU201) • Flat cable (LED exposure unit) • CCD board (CCDB) • Scanner drive board (SCDB) • Printer control board (PRCB) • MFP board (MFPB
Remedy: 1 Check the connection between SCDB PJ3-LU201, and correct if necessary. 2 Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary. 3 Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary. 4 Replace the LED exposure unit 5 Replace CCDB 6 SCDB F1 conduction check 7 Replace SCDB 8 Replace PRCB 9 Replace MFPB