Description: AC signal abnormality
Line frequency outside operating range of device.
Causes: Power supply unit (PU)
Remedy: 1 Check the power cord for continuity. Replace if necessary. 2 Make sure the nominal voltage source is within specification. Low-voltage models: 100 to 127 V AC High-voltage models: 220 to 240 V AC 3 Check if the power supply cable is properly connected to the CTLB. Reseat the cables if any abnormality is found 4 Measure the resistance between terminals A and D of the power supply socket. 1. Turn off the printer. 2. Remove the power cord. 3. Measure the resistance between terminals A and D of the power supply socket. 4. Is the resistance approximately 30 ohms? 5 Replace the PU if any abnormality is found in the measured resistance.