Code: C-1113
Description: SD: Exit open/close motor (M9) drive abnormality.
- When starting a pressure contact operation, the saddle exit home sensor (PS18) does not turn ON within a specified period of time after M9 turns ON.
- When starting a separation operation, PS18 does not turn OFF within a specified period of time after M9 turns ON.
- When starting a pressure contact operation, the saddle exit home sensor (PS18) does not turn ON within a specified period of time after M9 turns ON.
- When starting a separation operation, PS18 does not turn OFF within a specified period of time after M9 turns ON.
Causes: Exit open/close motor (M9) Saddle exit home sensor (PS18) SD control board (SDCB)