Mã lỗi C1113 — Konica-Minolta bizhub 502

Code: C1113

Description: Center-staple lead edge stopper motor malfunction <When FS-526+SD-508 is installed> • The leading edge stopper home sensor (PS32) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M22) is turned ON. <When FS-527+SD-509 is installed> • The leading edge stopper home sensor (PS45) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M20) is turned ON.
Causes: Leading edge stopper motor (M22) Leading edge stopper home sensor (PS32) SD drive board (SDDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M23 for proper drive coupling, and correct as necessary. 3 PS32 I/O check, sensor check SDDB CN407-8 (ON) SD-508 K-7 4 M22 operation check SDDB CN408<A>-1 to 6 (ON) SD-508 K-6 5 Change M22 6 SDDB ICP2 conduction check 7 Change SDDB 8 Change FSCB