Code: C1132
Description: Output OP punch driving motor malfunction <When FS-526+PK-516 is installed> • The PK punch oscillating home sensor (PS303) is turned neither ON nor OFF even after the set period of time has elapsed while the punch oscillating motor (M302) is energized.
Causes: Punch oscillating motor (M302) PK punch oscillating home sensor (PS303) Punch control board (PKDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M302 for proper drive coupling, and correct as necessary. 3 PS303 I/O check, sensor check PKDB CN37-2 (ON) PK-516 C-5 4 M302 operation check PKDB CN34-1 to 6 PK-516 C-5 5 Change M302 6 PKDB ICP1 conduction check 7 Change PKDB 8 Change FSCB