Code: C11E1
Description: Upper lower path switching motor drive malfunction <When FS-527 is installed> • The upper lower path switching sensor (PS26) is turned neither ON nor OFF even after the set period of time has elapsed after the upper lower path switching motor (M6) is turned ON.
Causes: Upper lower path switching motor (M6) Upper lower path switching sensor (PS26) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M6 for proper drive coupling, and correct as necessary. 3 PS26 I/O check, sensor check FSCB PJ21-9 (ON) FS-527 J-2 4 M6 operation check FSCB PJ9-1 (REM) FS-527 J-2 5 Change M6 6 Change FSCB