Code: C3B08
Description: IH input voltage error • While the IH heater was on, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was on, input voltage was at the low power detection value or under for more than the predetermined period of time.
Causes: IH coil unit IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the connection of the fusing unit. 2 Check the fusing unit, degaussing coil unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 3 Change degaussing coil unit 4 Change IHPU 5 Change PRCB 6 Change REDB