Description: Cooling fan failure • While the motor is running, the fan lock signal remains HIGH three times for a predetermined period of consecutive time. ADF
Causes: Cooling fan (FM1) DF control board (DFCB)
Remedy: 1 Check the connector of FM1 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check DFCB PJ7-1 to 3 DF-618 I-2 to 3 4 Change FM1 5 DFCB F7 conduction check 6 Change DFCB