Code: C1127
Description: Punch shift motor drive malfunction <When FS-526+PK-516 is installed> • The PK punch home sensor (PS301) is not turned ON even after the set period of time has elapsed while the punch drive motor (M301) is energized.
Causes: Punch drive motor (M301) PK punch home sensor (PS301) Punch control board (PKDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M301 for proper drive coupling, and correct as necessary. 3 PS301 I/O check, sensor check PKDB CN36-5 (ON) PK-516 C-3 4 M301 operation check PKDB CN35-1 to 3 PK-516 C-2 5 Change M301 6 PKDB ICP4 conduction check 7 Change PKDB 8 Change FSCB