Code: C1130
Description: 1st stopper motor drive malfunction <When FS-526+ZU-606 is installed> • The 1st folding stopper home sensor (PS603) is not turned ON even after the set period of time has elapsed after the 1st stopper motor (M602) starts searching home position.
Causes: 1st stopper motor (M602) 1st folding stopper home sensor (PS603) ZU control board (ZUCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M602 for proper drive coupling, and correct as necessary. 3 PS603 I/O check, sensor check ZUCB CN4-11 (ON) ZU-606 C-5 4 M602 operation check ZUCB CN15-4 to 6 ZU-606 C-3 5 Change M602 6 ZUCB ICP7 conduction check 7 Change ZUCB