Code: C1133
Description: Punch shift motor drive malfunction <When FS-526+ZU-606 is installed> • The punch shift home sensor (PS605) is not turned ON, or is not turned OFF after it is turned ON, even after the set period of time has elapsed after the punch shift motor (M605) starts searching its home position.
Causes: Punch shift motor (M605) Punch shift home sensor (PS605) ZU control board (ZUCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M605 for proper drive coupling, and correct as necessary. 3 PS605 I/O check, sensor check ZUCB CN3-2 (ON) ZU-606 C-6 4 M605 operation check ZUCB CN5-1 to 6 ZU-606 C-2 5 Change M605 6 ZUCB ICP5 conduction check 7 Change ZUCB