Code: C1183
Description: Elevate drive malfunction <When FS-527 is installed> • During downward movement, the tray 1 upper limit sensor (PS24) is turned OFF and the tray 1 lower limit sensor (PS21) is turned ON. • The elevate motor (M15) lock signal remains set to H for a set period of time while the elevate motor (M15) is turning. • The tray1 upper position switch (SW2) is turned ON even after the set period of time has elapsed while the elevate motor (M15) is energized. • The tray1 lower position switch (SW3) is turned ON even after the set period of time has elapsed while the elevate motor (M15) is energized.
Causes: Elevate motor (M15) Tray1 lower position sensor (PS21) Tray1 upper position sensor (PS24) Tray1 upper position switch (SW2) Tray1 lower position switch (SW3) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M15 for proper drive coupling, and correct as necessary. 3 PS21 I/O check, sensor check FSCB PJ21-3 (ON) FS-527 J-3 4 PS24 I/O check, sensor check FSCB PJ16-9 (ON) FS-527 J-4 5 SW2 I/O check, sensor check FSCB PJ3-2 (ON) FS-527 B to C-10 6 SW3 I/O check, sensor check FSCB PJ3-2 (ON) FS-527 B to C-10 7 M15 operation check FSCB PJ4-1 to 11 FS-527 B to C-4 8 Change M15 9 Change FSCB