Code: C11A1
Description: Tray 2 exit roller pressure/ retraction malfunction <When FS-527 is installed> • The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) is turned ON.
Causes: Exit roller retraction motor (M9) Exit roller pressure sensor (PS12) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M9 for proper drive coupling, and correct as necessary. 3 PS12 I/O check, sensor check FSCB PJ16-12 (ON) FS-527 J-4 4 M9 operation check FSCB PJ9-5 (REM) FS-527 J-1 5 Change M9 6 Change FSCB