Code: C3102
Description: Fusing roller failure to turn • When the IH power supply is turned ON, pulse signals are not input either of the heating roller rotation sensor within a predetermined period of time.
Causes: Heating roller rotation sensor/1 (PS56) Fusing motor (M30) Printer control board (PRCB) Fusing unit
Remedy: 1 Check the fusing unit for proper installation and correct as necessary. 2 Check the M30 connector for proper connection and correct as necessary. 3 PS56 I/O check, sensor check PRCB CN22-12 (ON) C-17 4 M30 operation check PRCB CN9-3 (REM) PRCB CN9-6 (LOCK) K-10 5 Change M30 6 Change fusing unit 7 Change PRCB