Code: C9402
Description: Exposure turning on the lamp abnormally detection • The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job. Scanner
Causes: Exposure unit Flat cable Inverter board (INVB) CCD board (CCDB) Scanner relay board (REYB/SCAN) MFP board (MFPB)
Remedy: 1 Check the connection between the lamp harness and the inverter board, and correct if necessary. 2 Check the connection between REYB/ SCAN and the inverter board, and correct if necessary. 3 Check the connection between REYB/ SCAN and MFPB, and correct if necessary. 4 Check that the connection between CCDB and MFPB, and correct if necessary. 5 Change INVB 6 Change exposure unit 7 Change CCDB 8 Change REYB/SCAN 9 Change MFPB