Mã lỗi C1143 — Konica-Minolta bizhub 554e

Code: C1143

Description: Leading edge paddle up/down motor’s malfunction. <When FS-535 is installed> The leading edge paddle home sensor (PS16) is not blocked or unblocked even after the set period of time has elapsed after the leading edge paddle up/down motor (M18) is turned ON.
Causes: • Leading edge paddle up/down motor (M18) • Leading edge paddle home sensor (PS16) • FS control board (FSCB)
Remedy: 1 Check the connector between M18-relay CN243-FSCB CN24 for proper connection, and correct as necessary. 2 Check the connector of M18 for proper drive coupling, and correct as necessary. 3 Check the connector between PS16-relay CN243- FSCB CN24 for proper connection, and correct as necessary. 4 PS16 I/O check, sensor check FSCB CN24-16 (ON) FS-535 9-L 5 M8 operation check FSCB CN24-17 to 20 FS-535 9-L 6 Replace M18 7 Replace FSCB