Description: Black TCR sensor adjustment failure. TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Developing unit • Toner bottle motor (M10) • Toner supply motor/K (M6) • Front side board (FRB) • Printer control board (PRCB)
Remedy: 1 Reinstall developing unit 2 Check the connector between developing unit-FRB CN13 for proper connection and correct as necessary. 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. 4 M10 operation check PRCB CN14-1 to 4 18-C 5 M6 operation check PRCB CN14-5 to 8 17 to 18-C 6 Replace the developing unit 7 Replace FRB 8 PRCB IC44, IC46 conduction check 9 Replace PRCB