Description: Fusing roller separation failure. • With the fusing roller being retracted, the fusing pressure home sensor (PS38) is not unblocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating. • With the fusing roller being pressed, the fusing pressure home sensor (PS38) is not blocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating.
Causes: • Fusing pressure motor (M11) • Fusing pressure home sensor (PS38) • Printer control board (PRCB) • Fusing unit
Remedy: 1 Check the connector between M11-relay CN112- PRCB CN13 for proper connection and correct as necessary. 2 Check the connector between fusing unit-relay CN95, CN96-PRCB CN4 for proper connection and correct as necessary. (bizhub 554e) Check the connector between fusing unit-relay CN98, CN99, CN104-PRCB CN5 for proper connection and correct as necessary. (bizhub 454e) 3 PS38 I/O check, sensor check PRCB CN4-9 (ON) (bizhub 554e) PRCB CN5-12 (ON) (bizhub 454e) - 4 M11 operation check PRCB CN13-1 to 4 bizhub 554e 26-C bizhub 454e 24-C 5 Replace M11 6 Replace the fusing unit (bizhub 554e/bizhub 454e) 7 PRCB IC26 conduction check 8 Replace PRCB