Description: Heating roller temperature sensor contamination (Main of the heating side). <bizhub 554e> When the machine is in standby mode after a predetermined period of time after the warm-up stage is started, detected temperature of the heating roller temperature sensor (TEMS) lower than a given temperature for a given period of time consecutively.
Causes: • Fusing unit • Heating roller temperature sensor (TEMS) • Printer control board (PRCB)
Remedy: 1 Wipe the TEMS clean of dirt if any. <Cleaning procedure> • Clear away a dirt or a foreign object on the sensor with a cotton swab. • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards. 2 Check the TEMS for installed position and proper connector connection. 3 Check the connection of the fusing unit. 4 Check the fusing unit and PRCB for proper connection and correct or change as necessary. 5 Replace the fusing unit 6 Replace PRCB