Description: IH coil cooling fan's failure to turn. <bizhub 554e> The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • IH coil cooling fan (FM7) • Expansion control board (EXCB) • Printer control board (PRCB)
Remedy: 1 Check the connector between FS7-relay CN77-EXCB CN5 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM7 operation check EXCB CN5-1 (REM) EXCB CN5-3 (LOCK) 23-T 4 Replace FM7 5 EXCB ICP1 conduction check 6 Replace EXCB 7 Replace PRCB