Description: At the time of operation other than the initial operation, the CIS cleaning sensor (PS7) error is detected.
Causes: • CIS cleaning sensor (PS7) • CIS cleaning motor (M5) • DF control board (DFCB)
Remedy: 1 Check if the opening and closing guide is firmly closed. 2 Check the connector between M5-DFCB J9 for proper connection, and correct as necessary. 3 Check the connector of M5 for proper drive coupling, and correct as necessary. 4 Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary. 5 PS7 I/O check, sensor check DRCB J13-3 (ON) DF-701 1-G 6 M5 operation check DRCB J9-1 to 4 DF-701 6-G 7 Replace M5 8 Replace DFCB