Code: C1115
Description: Center-staple knife drive motor malfunction <When FS-526+SD-508 is installed> • The center fold knife home sensor (PS34) is not turned ON even after the set period of time has elapsed while the center fold knife motor (M32) is energized. <When FS-527+SD-509 is installed> • The center fold plate home sensor (PS47) is turned neither ON nor OFF even after the set period of time has elapsed after the center fold plate motor (M26) is turned ON.
Causes: Center staple alignment motor /F (M20) Center staple alignment motor home sensor/F (PS30) SD drive board (SDDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M20 for proper drive coupling, and correct as necessary. 3 PS30 I/O check, sensor check SDDB CN403-14 (ON) SD-508 C-9 4 M20 operation check SDDB CN403-1 to 4 SD-508 C-8 5 Change M20 6 SDDB ICP4 conduction check 7 Change SDDB 8 Change FSCB