Code: C1136
Description: Punch switchover motor drive malfunction <When FS-526+ZU-606 is installed> • The punch switchover switch (MS601) is not turned OFF from the ON position, or not turned ON from the OFF position, even after the set period of time has elapsed after the punch switchover motor (M608) is turned ON.
Causes: Punch switchover motor (M608) Punch switchover switch (MS601) ZU control board (ZUCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M608 for proper drive coupling, and correct as necessary. 3 MS601 I/O check, sensor check ZUCB CN11-9 ZU-606 C-8 4 M608 operation check ZUCB CN11-8 (DRV) C-7 to 8 5 Change M608 6 ZUCB ICP9 conduction check 7 Change ZUCB