Code: C1151
Description: Center-staple stapler drive motor malfunction <When FS-526+SD-508 is installed> • The stapler home sensor (PS33) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple motor (M23) is turned ON.
Causes: Center staple motor (M23) Stapler home sensor (PS33) SD drive board (SDDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M23 for proper drive coupling, and correct as necessary. 3 PS33 I/O check, sensor check SDDB CN403-17 (ON) SD-508 C-10 4 M23 operation check SDDB CN406<A>-1 to 4 (ON) SD-508 K-8 5 Change M23 6 SDDB ICP4 conduction check 7 Change SDDB 8 Change FSCB