Code: C2152
Description: Transfer belt pressure welding alienation • At the completion of transfer belt pressure/ retraction operations, the pressure welding alienation sensor/K is not in the status corresponding to each of the transfer belt pressure/ retraction operations. • Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the pressure welding alienation sensor/K is not in the status corresponding to each of the transfer belt pressure/retraction operations.
Causes: Pressure welding alienation sensor/K (PS51) 1st image transfer pressure retraction motor (M21) Printer control board (PRCB)