Description: Fusing cooling fan motor/ 3 failure to turn • The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing cooling fan motor/3 (FM5) Paper feed/transport drive board (PFTDB)
Remedy: 1 Check the FM5 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM5 operation check PFTDB CN5-9 (REM) PFTDB CN5-11 (LOCK) Q-7 4 Change FM5 5 PFTDB ICP2 conduction check 6 Change PFTDB