Description: LCT up/down abnormality • The Upper limit sensor (PS2) is not blocked even after the set period of time has elapsed after the paper lift-up operation began.
Causes: Upper limit sensor (PS2) Lift-up motor (M1)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 PS2 I/O check, sensor check LUDB CN5-3 (ON) LU-204 G-4 4 M1 operation check LUDB CN3-4 (ON) LU-204 G-3 5 Change M1 6 LUDB ICP2 conduction check 7 Change LUDB