Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C1106 — Konica-Minolta bizhub 652

Code: C1106

Description: Side-staple stapler drive malfunction <When FS-526 is installed> • The stapler position sensor/1/2/3/4 (PS50/ PS/51/PS52/PS53) is turned neither ON nor OFF even after the set period of time has elapsed after the 2 staples stapler movement motor (M13) is turned ON.
Causes: 2 staples stapler movement motor (M13) Stapler position sensor/1 (PS50) Stapler position sensor/2 (PS51) Stapler position sensor/3 (PS52) Stapler position sensor/4 (PS53) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M13 for proper drive coupling, and correct as necessary. 3 PS50 I/O check, sensor check FSCB CN20<B>-3 (ON) FS-526 L-13 4 PS51 I/O check, sensor check FSCB CN20<B>-6 (ON) FS-526 L-13 5 PS52 I/O check, sensor check FSCB CN20<B>-9 (ON) FS-526 L-13 to 14 6 PS53 I/O check, sensor check FSCB CN20<B>-12 (ON) FS-526 L-14 7 M13 operation check FSCB CN15-3 to 8 FS-526 D-11 to 12 8 Change M13 9 FSCB ICP5 conduction check 10 Change FSCB

← Xem tất cả mã lỗi Konica-Minolta bizhub 652

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin