Code: C1190
Description: Alignment plate motor drive malfunction <When FS-527 is installed> • The alignment plate home sensor (PS17) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment plate motor (M13) is turned ON.
Causes: Alignment plate motor (M13) Alignment plate home sensor (PS17) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of M13 for proper drive coupling, and correct as necessary. 3 PS17 I/O check, sensor check FSCB PJ17-3 (ON) FS-527 B to C-8 4 M13 operation check FSCB PJ8-1 to 4 FS-527 B to C-7 5 Change M13 6 Change FSCB