Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C2152 — Konica-Minolta bizhub 652

Code: C2152

Description: Transfer belt pressure welding alienation • At the completion of transfer belt pressure/ retraction operations, the pressure welding alienation sensor/K is not in the status corresponding to each of the transfer belt pressure/ retraction operations. • Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the pressure welding alienation sensor/K is not in the status corresponding to each of the transfer belt pressure/retraction operations.
Causes: Pressure welding alienation sensor/K (PS51) 1st image transfer pressure retraction motor (M21) Printer control board (PRCB)
Remedy: 1 Check the M21 connector for proper connection and correct as necessary. 2 PS51 I/O check, sensor check PRCB CN21-1 (ON) C-23 3 M21 operation check PRCB CN20-1 to 4 K-8 4 Change M21 5 PRCB ICP4 conduction check 6 Change MFPB

← Xem tất cả mã lỗi Konica-Minolta bizhub 652

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie