Description: Fusing motor failure to turn • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing motor (M30) Printer control board (PRCB)
Remedy: 1 Check the M30 connector for proper connection and correct as necessary. 2 Check the loading status of the fusing unit drive, and correct the error as necessary. 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary. 4 M30 operation check PRCB CN9-3 (REM) PRCB CN9-6 (LOCK) K-10 5 Change M30 6 PRCB ICP16 conduction check 7 Change PRCB