Code: C3925
Description: Fusing sensor wire breaks detection (NC sensor) • At the warm-up stage, the heating roller temperature sensor/1 voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time.
Causes: Fusing unit Heating roller temperature sensor/1 (TEMS1) Heating roller temperature sensor/2 (TEMS2) Heating roller temperature sensor/3 (TEMS3) IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 4 Change TEMS1, TEMS2 or TEMS3 5 Change fusing unit 6 Change IHPU 7 PRCB ICP17 conduction check 8 Change PRCB 9 Change REDB