Description: Tray 2 feeder up/down abnormality. The tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Causes: • Tray 2 upper limit sensor (PS14) • Tray 2 lift-up motor (M8) • Paper feed/transport drive board (PFTDB) • Printer control board (PRCB)
Remedy: 1 Check the connector between M8-PFTDB CN26 for proper connection and correct as necessary. 2 Check the connector of M8 for proper drive coupling and correct as necessary. 3 Check the connector between PS14-relay CN155BPFTDB CN14 for proper connection and correct as necessary. 4 PS14 I/O check, sensor check PFTDB CN14-9 (ON) 4-P 5 M8 operation check PFTDB CN26-10 to 11 4-X 6 Replace M8 7 PFTDB ICP10 conduction check 8 Replace PFTDB 9 Replace PRCB