Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C3922 — Konica-Minolta bizhub 654

Code: C3922

Description: • Fusing sensor wire breaks detection (Edge of the heating roller) • Fusing unit for incorrect marketing area (The fusing unit for incorrect marketing area is installed) After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/3 voltage does not change by predetermined steps within a predetermined period of time.
Causes: • Fusing unit • Heating roller thermistor/3 (TH3) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Check the marketing area of the fusing unit. If the marketing area is incorrect, replace the fusing unit for proper marketing area. 5 Replace the fusing unit 6 Replace IHPU 7 Replace PRCB 8 Replace NF1

← Xem tất cả mã lỗi Konica-Minolta bizhub 654