Description: Lift up mechanism failure (Downward movement) The lift up lower sensor (PS3) is not blocked after a lapse of a given time after the lift-up motor (M5) goes down (is turned backward).
Causes: • Lift-up motor (M5) • Lift-up lower sensor (PS3) • DF control board (DFCB)
Remedy: 1 Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 Check the connector between PS3-DFCB CN12 for proper connection, and correct as necessary. 4 PS3 I/O check, sensor check DFCB CN12-12 (ON) DF-702 12-C 5 M5 operation check DFCB CN11-4 to 7 DF-702 13-C 6 Replace M5 7 DFCB ICP13 conduction check 8 Replace DFCB