Description: IH power supply cooling fan's failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • IH power supply cooling fan (FM10) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM10-relay CN293- PRCB CN5 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM10 operation check PRCB CN5-1 (DRIVE) PRCB CN5-3 (LOCK) 9-K 4 Replace FM10 5 PRCB ICP24 conduction check 6 Replace PRCB